Module Name
iLO 5 Cryptographic Module
Validation Dates
02/08/2018
Caveat
When installed, initialized and configured as specified in the Security Policy Section 3
Security Level Exceptions
- Mitigation of Other Attacks: N/A
Embodiment
Multi-Chip Embedded
Description
The HP Integrated Lights-Out 5 (HP iLO 5) built into HP ProLiant Gen10 and Synergy(480 and 660) servers is an autonomous secure management component embedded directly on the server motherboard. iLO helps simplify initial server setup, power and thermal optimization, remote server administration, and provides server health monitoring with the HP Active Health System (AHS).
FIPS Algorithms
AES |
Certs. #4467 and #4525 |
CKG |
vendor affirmed |
CVL |
Certs. #1201 and #1202 |
DRBG |
Cert. #1485 |
DSA |
Cert. #1204 |
ECDSA |
Cert. #1100 |
HMAC |
Cert. #2985 |
KBKDF |
Cert. #132 |
KTS |
AES Cert. #4525 and HMAC Cert. #2985; key establishment methodology provides between 128 and 256 bits of encryption strength |
RSA |
Cert. #2462 |
SHS |
Certs. #3679 and #3706 |
Triple-DES |
Cert. #2412 |
Allowed Algorithms
Diffie-Hellman (CVL Cert. #1202, key agreement; key establishment methodology provides 112 or 128 bits of encryption strength); EC Diffie-Hellman (CVL Certs. #1201 and #1202, key agreement; key establishment methodology provides 128 or 192 bits of encryption strength); MD5; NDRNG; RSA (CVL Cert. #1202, key wrapping; key establishment methodology provides between 112 and 128 bits of encryption strength)
Hardware Versions
ASIC (GXP: 815393-001) with Flash Memory (1819-1208), NVRAM (1819-1209), and DDR3 SDRAM (2660-0461)